arrow-left feather Flag of the People's Republic of China flag-deFlag of Germany flag-es flag-jp flag-rumail marker media-archive media-default media-document phone rotate-right search social-googleplus social-linkedin social-youtube
Contact

ASTM D7094 Flash Point Testing with the ERAFLASH Series

ASTM D7094 flash point testing is the future-proof replacement for ASTM D93 Pensky-Martens testers, bringing 100% safety, unrivalled speed as well as best in class precision to your laboratory. With the wide temperature range of -40 °C to 420 °C (-40 °F to 788 °F) all kinds of liquids can be tested using only 1 or 2 mL of sample. Take a glance at our method comparison, our unique flash point testing solutions, and our latest application note. And don’t miss our latest overview brochure on the entire flash point series: DOWNLOAD BROCHURE >>

1. ASTM D7094 vs ASTM D93: A Comparison >>

2. Our solutions for Flash Point Testing >>

3. Application Note Flash Point Testing >>

 

1. ASTM D7094 vs ASTM D93: A Comparison

Check out the game changing advantages of flash point measurement according to ASTM D7094:

ASTM D7094 ASTM D93
100 % Safe: no open flame, no glowing wire, no risk of fire in the lab Risk of fire in the lab, built-in fire extinguishers required
Super-fast: 2 times faster turnaround time: A typical diesel measurement at 60 °C takes only 11 minutes A typical diesel measurement takes about 22 minutes
Best in class precision for the widest sample and temperature range Limited range of applications
Sample volume of only 2 mL Sample volume of 75 mL
Easy cleaning, practically no waste Time-consuming cleaning procedure and expensive waste disposal

 

2. Our solutions for THE NEXT ERA of flash point testing:

 

eralytics NEXT ERA flash point testers are known for their safe, fast and precise measurements and offer a flash point solution for every application. Our flash point testers comply to the inherently safe CCCFP – Continuously Closed Cup Flash Point methods ASTM D6450, ASTM D7094 and IP 620 and are meeting the highest safety standards. With different models and unique measuring options eralytics offers a solution for every flash point testing application over the widest possible measuring range from -40 °C (-40 °F) to 420 °C (788 °F).

ERAFLASH The Allround Flash Point Tester
The high-end allrounder for all kinds of samples |  More on ERAFLASH >>

ERAFLASH S10 The Flash Point Autosampler
The high-speed sampler for heavy work loads | More on ERAFLASH S10 >>

ERAFLASH LT – The Low Temperatur Flash Point Tester
The cooling star for tests down to -40 °C | More on ERFLASH LT >>

ERAFLASH X – The Next Era Flash Point Tester
The future-proof replacement for ASTM D93 Pensky-Martens testers | More on ERFLASH X >>

3. Application Note Flash Point Testing

Have you ever asked yourself why an ASTM D7094 flash point test is twice as fast as an ASTM D93 Pensky Martens test? Check out our latest application report:

“ERAFLASH: Efficiency through maximum safety and measuring speed”